Reichert® Tono-Vera® Tonometer - Rechargeable Model

SKU:
16306
Availability:
Order Now – Trade-in offer available, details below! Due to demand, orders placed today will ship in 1-2 weeks. For purchase online in USA ONLY, price shown in USD. Credit cards are charged when order is placed. Call 1-800-866-6736 for availability.
On Sale
  • Reichert® Tono-Vera® Tonometer - Rechargeable Model
  • Tono-Vera Tonometer measuring patient
  • Tono-Vera Tonometer successful measurement from patient
  • Tono-Vera Tonometer measuring patient using Ocu-Dot Probe
  • Tono-Vera Tonometer measuring pediatric patient
  • Tono-Vera Tonometer measuring patient
  • Ocu-Dot Probes
  • Tono-Vera Tonometer in base on counter
Now: $4,299.00
Was: $4,799.00
Frequently bought together:

Description

For a limited introductory period, purchase the all-new Reichert® Tono-Vera® Tonometer and receive a $500 instant rebate (markdown price reflected above) PLUS a $750 trade-in rebate when you trade in any tonometer, once you receive your Tono-Vera, for a total savings of $1,250! Offer valid through 12/31/2024. See offer details or Request Quote»

Tono-Vera® Tonometer with
ActiView™ Positioning System – Now Available!


Truly Objective Tonometry from a Refinded Rebound Tonometer

Introducing the all-new Reichert® Tono-Vera® Tonometer featuring the advanced, patented ActiView™ Positioning System, your guided view to precise IOP measurements, which quickly guides you to the apex of the cornea. Using gentle rebound tonometer technology and eliminating the need for topical anesthetic, Tono-Vera automatically measures when aligned. Tono-Vera provides more objective and repeatable results giving you confidence in your intraocular pressure (IOP) readings. For nearly 200 years, Reichert continues to advance tonometry, refraction, and dry eye diagnostics through continuous innovation!

 


A more objective measurement with ActiView™

The Tono-Vera® ActiView™ Positioning System features a full color view of the eye combined with intuitive, interactive alignment prompts to guide the user precisely to the apex of the cornea. When proper alignment is achieved Tono-Vera automatically measures, providing a result in as few as three measurements. Intuitive color-coded rings indicate the reliability of the reading.

 

All the important information, always on display

Tono-Vera has a comprehensive yet clutter-free user interface.

 

Tono-Vera Tonometer, innovative and thoughtfully designed

Lightweight, Ergonomic, and Calibration-free

The perfectly placed operator-facing display and lightweight, symmetrical design allow for comfortable left or right-handed operation. Intuitive button placement provides easy access to all settings and measurement functions. Always ready to measure with no routine calibration required.

Rechargeable, AA, or Both

Tono-Vera is available in two models – Rechargeable or AA Battery. Rechargeable Model means fewer batteries in landfills and a device that is always ready to use. AA Battery Model goes anywhere and allows for a quick and easy battery change with no additional tools required. Rechargeable and AA Battery Packs are interchangeable, providing ultimate flexibility.

A Base for Everything & Everything in its Place

The included multi-purpose Tono-Vera Base is the perfect solution for docking Tono-Vera and charging your Rechargeable Model, while also conveniently storing and dispensing Ocu-Dot® Tonometer Probes.

Ready for the Road

When your patients can’t come to you, bring Tono-Vera to them in the durable, lightweight, and protective carry case.

Comfort and Control

Innovative FlexiSoft™ Forehead Rest has been designed for easy distance control and patient comfort.

Electronic Health Record Ready

Tono-Vera is Bluetooth enabled, allowing for software updates and Electronic Health Record connectivity.


Ocu-Dot® Tonometer Probes

Specially designed for Tono-Vera Tonometers, Ocu-Dot® Tonometer Probes are single-use, individually packaged for fast and easy loading, and come in boxes of 100 count.

 

Improving eye care through continuous innovation

At Reichert®, we stand by our products giving Tono-Vera Tonometer a two-year warranty.
Tono-Vera is designed, engineered, and assembled in Buffalo, New York, USA.

 

Reichert is Technology, Tradition & Trust

For over 75 years, Reichert has paved the way for continuous advancement in tonometry and glaucoma diagnostics. With the introduction of Tono-Vera, Reichert now offers the most comprehensive line of tonometry solutions.

Reichert is a global innovation leader in tonometry, offering a wide-range of tonometry options including Reichert® 7CR Auto Tonometer with Corneal Compensated IOP (IOPcc), Ocular Response Analyzer® G3 with Corneal Hysteresis +IOPcc, the unique Model 30™ Pneumatonometer with tonography and ocular pulse amplitude, the award-winning Tono-Pen AVIA® with QuickTap® Measurement Mode, and now the advanced Tono-Vera Tonometer with ActiView Positioning System.

 

Specifications:

Catalog Number:
16306 Tono-Vera® Rechargeable Starter Kit

Includes:
• Tono-Vera
• Tono-Vera Carrying Case
• Tono-Vera Charging Base
• Tono-Vera Li-Ion Rechargeable Battery Pack
• Tono-Vera Training Aid
• Tono-Vera Spare Probe Chamber Kit
• Ocu-Dot® Tonometer Probes - 100 count
• USB-C Charging Cable
• Charging Plug

Weight: 4.2 oz. (120.3 g)
Length: 8.4 in. (21.25 cm)
Width: 2.6 in. (6.6 cm)
Thickness: 1.2 in. (3.0 cm)
Measurement Range: 5-60 mmHg (Display range 1-99 mmHg)
Accuracy: ±1.0 mmHg (5-20 mmHg), ±1.7 mmHg (21-60 mmHg)
Power Source: Tono-Vera Li-Ion Rechargeable Battery Pack or Tono-Vera AA Battery Pack

 

 

*This device may not be cleared for sale in all countries.

 

 